45.6.5
Requirements
Access step-by-step
Setup

Resection/Resection Helmert

For TPS1200 the coordinates of the station point are unknown. The coordinates and orien-
tation are determined by sighting to one or more known target points (maximum of ten target
points). Only angles or both angles and distances may be measured. For a resection, least
squares or robust calculations are used. For a resection Helmert, Helmert calculations are
used.
Refer to the stated chapter for more information on screens.
Description
1.
Press PROG to access the Programs menu.
2.
Select and activate Setup to move to the first screen.
3.
Press CONT (F1) to access SETUP Station Setup.
4.
<Method:> Select either Resection or Resection Helmert.
<Station ID:> Enter the instrument station.
<Instrument Ht:> Enter the height of the instrument station.
<Fixpoint Job:> Select the fixpoint job of the control/target points.
5.
<Fixpoints:> Select the method for measuring the control/target points.
Select Meas All Now if a "Standard" setup is required.
Select Add Points Later if an "On-the-Fly" setup is required.
6.
Press CONT (F1) to access SETUP Measure Target.
7.
SETUP Measure Target
TPS1200
Refer to
chapter
45.2
45.2
45.6.4