Setup With Smartpole - Leica TPS1200 series Technical Reference Manual

Hide thumbs Also See for TPS1200 series:
Table of Contents

Advertisement

45.5
Access step-by-step
Setup

Setup with SmartPole

Description
1.
Access SETUP Station Setup Begin.
2.
SETUP Station Setup Begin
Check the settings and ensure that a coordinate system other than <None> or
WGS84 is selected and attached to the active job.
3.
CONT (F1) to access SETUP Station Setup.
4.
SETUP Station Setup
Choose one of the following setup methods:
• <Method: Known BS Point> or
• <Method: Ori & Ht Transfr>, or
• <Method: Resection> or
• <Method: Resection Helmert>.
These are the only methods applicable for a setup with SmartPole.
All setup methods are described in "45.6 Setup Methods".
5.
<Station Coord:> If available, select the source for the instrument station coordinates
<Station ID:> Enter/Select the instrument station
<Instrument Ht:> Enter the height of the instrument station
<Fixpoint Job:> Select the fixpoint job of the control/target points
6.
<Fixpoints:> If available, select the method for measuring the control/target points.
Select Meas All Now if a "Standard" setup is required.
TPS1200
1111