8.6
Description
Access
Backsight Check
☞
8.7
Description
Access
Notes
Favourites
EDM Mode
Tracking mode OFF! <=> Tracking mode ON!
Prism
Precise+ <=> Tracking / Precise&Fast <=> Tracking
Non-Prism
NP-Precise <=> NP-Tracking
The last active measurement mode remains set when the instrument is
switched off.
Backsight Check
This favourite enables the user to remeasure to the point(s) used for Station
Setup. This is useful to check if the station position is still correct after measur-
ing some points.
1.
Press the Favourites key when within any app.
2.
Select BS-Check from the Favourites Menu.
This screen is exactly the same as the Setout screen, except that the available
PtIDs are restricted to the points used for the last orientation. Refer to "7.4
Setout" for information about the screen.
When setting up a station by local resection, check the coordinate system of
the points used from the list.
SketchPad
The field sketch functionality is used to create a sketch on virtual paper.
The sketch is stored as image in bmp format. The bmp file is stored in the
\JOBS\IMAGES folder of the internal memory. The predefined template is opti-
mised for A4 printout.
1.
Press the Favourites key when within any app.
2.
Select SketchPad from the Favourites Menu.
151