Leica TPS1200 series Technical Reference Manual page 1288

Hide thumbs Also See for TPS1200 series:
Table of Contents

Advertisement

Traverse
Close traverse with
angular closure step-
by-step
Step
Description
CHECK (F3) to check the point. The fields are the same as in
TRAVERSE Traverse Results.
NRMAL (F5) to measure a foresight point.
10.
CLOSE (F1) to use the point as closing point
11.
TRAVERSE Foresight, Set:X/X
12.
ALL (F1) to measure and record the closing point.
13.
Repeat step 12. until all sets are measured.
14.
TRAVERSE Point Statistics, Pt:X/X
15.
CONT (F1) to view traverse Results.
16.
TRAVERSE Traverse Results
CONT (F1) to choose to close angle, to measure sideshot point, to
view traverse data or to end traverse.
17.
END T (F6) to end the traverse without angular closure.
Step
Description
1.
Repeat steps 1. to 16. from paragraph "Close traverse without
angular closure step-by-step".
2.
C ANG (F1) to close the traverse with angular closure.
3.
Move to the closure point and start Traverse application program.
TPS1200
1288
Refer to
chapter
51.6
51.5
51.6
Refer to
chapter
51.4.3
51.2

Advertisement