Stakeout
Step
Description
Check the other settings.
7.
CONT (F1) to access STAKEOUT DTM Stakeout.
8.
STAKEOUT DTM Stakeout, Stake page
Check the suggested reflector height.
9.
DIST (F2).
10.
STAKEOUT DTM Stakeout, Stake page
<CUT:> or <FILL:> The negative or positive height difference from
the current position to the equivalent point in the selected DTM job is
calculated and displayed. Height offsets apply for whole DTM.
11.
Mark the current position.
12.
REC (F1) to store distance and angles.
For <Height Check: Yes> in STAKEOUT Configuration, Checks
page, a check is made on the vertical coordinate distance from the
staked point to the point to be staked. If the configured difference limit
is exceeded, STAKEOUT Difference Limit Exceeded is accessed.
13.
Are more heights to be staked?
If yes, move to the next position and repeat steps 8. to 13.
If no, continue with step 14.
14.
SHIFT QUIT (F6) to return to the screen from where STAKEOUT
Stakeout Begin was accessed.