Stake out a DTM
step-by-step
Stakeout
The following table explains the most common settings. Refer to the stated chapter for more
information on screens.
Step
Description
DTM Stakeout must be activated via a licence key.
The DTM job to be used must be stored in the \DBX directory on the
active memory device.
1.
Start the Stakeout application program.
2.
STAKEOUT Stakeout Begin
CONF (F2) to access STAKEOUT Configuration.
3.
PAGE (F6) until the Heights page is active.
4.
STAKEOUT Configuration, Heights page
<Use DTM: DTM only>
<Use DTM: DTM & Stake Job> is not covered in this step-by-step
instruction. The stake out procedure is identical as described for the
selected <Stake Mode:>. The heights to be staked are taken from
the selected <DTM Job:> defined in STAKEOUT Stakeout Begin.
This step-by-step instruction uses typical settings in all other fields on
all pages in STAKEOUT Configuration.
The selection for <Stake Mode:> is irrelevant since no positions are
staked.
5.
CONT (F1) to access STAKEOUT Stakeout Begin.
6.
STAKEOUT Stakeout Begin
<DTM Job:> Select a DTM job.
TPS1200
Refer to
chapter
28
46.2
46.3
46.3
46.3
46.2
1193