45.6.4
Requirements
Access step-by-step
Setup

Orientation and Height Transfer

For TPS1200 the position coordinates of the station point are required. The instrument is
set up and oriented to one or more known backsight targets.
For SmartStation the position coordinates of the station are unknown and are determined
with GPS real-time. The instrument is set up and oriented to one or more known backsight
targets.
For TPS1200 and SmartStation the orientation is determined by sighting to one or more
known target points (maximum of ten target points). Only angles or both angles and
distances may be measured. The height of the station point can also be derived from the
target points.
Refer to the stated chapter for more information on screens.
Description
1.
Press PROG to access the Programs menu.
2.
Select and activate Setup to move to the first screen.
3.
Press CONT (F1) to access SETUP Station Setup.
4.
<Method:> Ensure that Ori & Ht Transfr is selected.
<Station Coord:> Select the source for the instrument station coordinates.
<Station ID:> Enter/Select the instrument station.
<Instrument Ht:> Enter the height of the instrument station.
<Fixpoint Job:> Select the fixpoint job of the control/target points.
5.
<Fixpoints:> Select the method for measuring the control/target points.
TPS1200
Refer to
chapter
1131