Setup
SETUP
Survey Survey
Description
Select Add Points Later if an "On-the-Fly" setup is required.
Steps 7. and 8. do not relate to <Method: Known BS Point>.
7.
CONT (F1) to access SETUP Measure Target 1.
8.
SETUP Measure Target 1
Refer to "45.6.4 Orientation and Height Transfer" for details on all fields and keys.
9.
GPS (F4) to access SETUP Survey Survey.
10.
SETUP Survey Survey
This is the GPS Survey screen within the Setup program. The target points can be
measured with GPS, which can then be used as fixpoints for the station setup.
• OCUPY (F1) To start the point occupation.
• STOP (F1) To end the point occupation.
• STORE (F1) To store the point information.
Overview of the screen
Important feaures about this screen:
• Upon entering SETUP Survey Survey SmartPole switches into GPS mode.
• The display mask for SETUP Survey Survey is configurable.
• A coordinate system for the setup is required and should be attached to the active job.
• If not already on, SmartAntenna is automatically turned on upon entry to the screen.
• Some of the screen icons change from TPS specific to GPS specific.
• The occupation/storing behaviour is dependent on the configuration settings.