Survey - Auto Points
Field
Option
Stop & Go
User Decides An auto point is stored uppon pressing REC (F3) in
<Log Every:>
User input
TPS1200
Description
An auto point is stored when the position of the
reflector does not move more than the distance
configured in <Stop Position:> within the <Stop
Time:>.
Once a point has been stored, the position from the
point just stored must change more than the
distance configured in <Stop Position:> before he
routine starts again.
SURVEY Survey: Job Name, Auto page. In the
beginning, the chain to which the auto points should
be assigned must be started with START (F1). In the
end, the chain must be closed with STOP (F1).
Available when:
• <Log By: Time>
• <Log By: Distance>
• <Log By: Height Diff>.
User input when:
• <Log By: Distance>
• <Log By: Height Diff>
• <Log By: Dist or Ht>
• <Log By: Stop & Go>.
1210