Setup
45.7.2
Description
Access
SETUP

Additional Information,

Status page
Additional Information
The SETUP Additional Information screen displays information about the accuracy of
the measured target points and allows exclusion of measurements that are not to be used
in the calculation.
Additional measurements can be made and measurements can be deleted.
Press INFO (F4) in the SETUP Results screen.
TPS1200
RECLC (F1)
To recalculate the station data and update all
values after target points have been deleted or
excluded from the calculation. Returns to the
SETUP Results screen.
USE (F3)
To decide whether or not to use a target point
in the calculation. Changes the value in the
Use column.
REMOV (F4)
To delete a point from the list of measured
target points and exclude it from the Setup
calculation.