This function activates or deactivates the tracking measurement mode. The new
setting is displayed for about one second and then set. The function can only be
activated from within the same EDM mode and prism type. The following options are
available.
EDM Mode
Tracking measurement mode
Off <=> On
Prism
Prism-Standard <=> Prism-Tracking / Prism-Fast <=> Prism-Tracking.
Non-Prism
Non-Prism-Standard <=> Non-Prism-Track.
The last active measurement mode remains set when the instrument is switched off.

Backsight Check

This function enables the user to remeasure to the point(s) used for Station Setup.
This is useful to check if the station position is still correct after measuring some
points.
1. Press FNC when within any application.
2. Select Backsight Check from the FUNCTIONS menu.
FlexLine, 87