51.4.3
Close traverse without
angular closure step-
by-step
Traverse
Closing Traverse
Step
Description
1.
Refer to paragraph "Measure traverse step-by-step" to measure a
traverse.
2.
Start the Traverse application program.
3.
TRAVERSE Traverse Begin
Check the settings.
4.
CONT (F1) to access TRAVERSE Traverse Information.
5.
TRAVERSE Traverse Information
The existing traverse is shown
DATA (F5) to view data of the active traverse.
END T (F6) to end the existing traverse.
SHIFT CONF (F2) to change the configuration settings.
6.
CONT (F1) to access TRAVERSE Backsight, Set:X/X.
Enter <Instrument Ht:>
7.
ALL (F1) to measure and record the backsight point.
8.
TRAVERSE Foresight, Set:X/X
SHIFT GETPT (F4) to get a point from the <Fixpoint Job:> which
can be used to close the traverse.
9.
CONT (F1) to select the highlighted point.
TPS1200
Refer to
chapter
51.4.2
51.2
51.5
51.3
1287