Setup
Description of fields
Field
Option
<Backsight ID:>
Choicelist
<Reflector Ht:>
User input
<Calc Azimuth:>
Output
<Calc HDist:>
Output
<∆Horiz Dist:>
Output
MORE (F5)
Available on the Setup page. Toggles between
the displayed values. As default the
for azimuth, horizontal distance and height are
shown. If MORE (F5) is pressed, the display
changes to the measured values of azimuth,
horizontal distance and height.
PAGE (F6)
To change to another page on this screen.
Description
Backsight point ID. All 3D and 2D points from
<Fixpoint Job:> can be selected.
The default reflector height as defined in the active
configuration set is suggested.
Displays the calculated azimuth from the selected
station to the backsight point.
Displays the calculated horizontal distance between
the selected station and backsight point.
The difference between the calculated horizontal
distance from station to backsight point and the
measured distance.
TPS1200
∆
values
1127