Setup
Description of fields
Field
Option
<Station ID:>
User input
TPS1200
INFO (F4)
To display additional information about the
accuracy of the measured target points and to
delete inconsistent measurements in the
SETUP Additional Information screen.
DONE (F5) (Applicable to Add Points Later)
To temporarily exit the Setup program. The
station setup will be incomplete but can be
continued and completed at a later time.
SURVY (F5) (Applicable to Meas All Now)
To access SETUP Measure Target and to
measure more target points.
PAGE (F6)
To change to another page on this screen.
SHIFT ELL H (F2) or SHIFT ORTH (F2)
Changes between the ellipsoidal and the ortho-
metric height.
SHIFT 3 PAR (F2) or SHIFT 4 PAR (F2)
Switches between a 3 parameter and 4 param-
eter helmert calculation. The results are imme-
diately updated.
SHIFT OTHER (F5)
Available if two solutions were calculated.
Changes between these solutions.
Description
Station ID of the current station set up.