Hidden Point
Step
Description
SHIFT INDIV (F5) for an individual point ID independent of the ID
template. SHIFT RUN (F5) changes back to the next ID from the
configured ID template.
7.
ALL (F1) measures reflector 1 and accesses HIDDEN PT Measure
Reflector 2.
8.
Repeat step 7. for reflector 2 and for reflector 3.
After the last reflector of the hidden point rod is measured,
HIDDEN PT Hidden Point Result, Results page is accessed.
9.
HIDDEN PT Hidden Point Result, Result page
<Point ID:> The name of the hidden point. The configured point ID
template is used.
<Hz:>, <V:> and <Slope Dist:> The calculated horizontal and
vertical angle and slope distance to the computed hidden point. -----
is displayed for unavailable information.
<Ht Diff:> The calculated height difference from instrument to
computed hidden point. ----- is displayed for unavailable information.
<Easting:>, <Northing:> and <Ortho Ht:> The calculated coordi-
nates of the computed hidden point. ----- is displayed for unavailable
information.
NEXT (F5) to store the hidden point and to access HIDDEN PT
Measure Reflector 1.