Reference Line
Description of fields
Field
Option
<Task:>
TPS1200
CONT (F1)
To accept changes and continue with the
subsequent screen.
SLOPE (F3)
To set a slope from a defined reference
line/arc. Cut/Fill values can then be displayed
to the slope when measurements are taken
along the reference line/arc.
OFSET (F4)
To set horizontal and vertical offsets, shifts
and rotations on the defined reference line or
to set horizontal and vertical offsets on a
defined reference arc.
SURVY (F5)
Available for <Ref to Use: Manually Enter>
when a point field is highlighted. To measure a
point.
PAGE (F6)
To change to another page on this screen.
SHIFT CONF (F2)
To configure the reference line/arc.
Description
Defines the task to be performed.
962