45.6
45.6.1
Description
Access
Setup

Setup Methods

Setup Reminder

When activated, the setup reminder function displays a screen which enables the user to
check the current station setup details before proceeding with the survey. When this
screen appears, three options are available to the user:
• 1. To keep the current station setup and proceed with the survey.
• 2. To create a new station setup.
• 3. To check the backsight point.
The setup reminder function is available to every application program, except:
• Alignment Tool Kit
• Determine Coordinate System
• Setup
• Traverse
When the setup reminder function is activated (refer to "45.3 Configuring Setup"), the current
station setup details are displayed whenever CONT (F1) is pressed in a Begin screen in an
application program.