Leica TPS1200 series Technical Reference Manual page 1185

Hide thumbs Also See for TPS1200 series:
Table of Contents

Advertisement

Stakeout
Step
Description
1.
Set up and orient the instrument.
<Automation: LOCK> and <EDM Mode: Tracking> are configured
in CONFIGURE EDM & ATR Settings.
2.
Start the Stakeout application program.
3.
STAKEOUT Stakeout Begin
Check the settings.
4.
CONF (F2) to access STAKEOUT Configuration, General page.
5.
STAKEOUT Configuration, General page
<Stake Mode: Ortho from Stn>
This step-by-step instruction uses typical settings in all other fields on
all pages in STAKEOUT Configuration.
6.
CONT (F1) to access STAKEOUT Stakeout Begin.
7.
CONT (F1) to access STAKEOUT Orthogonal Stakeout.
8.
STAKEOUT Orthogonal Stakeout, Stake page
Check the suggested point ID and the reflector height.
9.
DIST (F2).
10.
Move to the point to be staked either by following the range informa-
tion in the fields <FORW:>, <BACK:>, <RGHT:> and <LEFT:> or the
graphical display.