Parameter
Description
hcalarm alarm
The identifier of the hcalarm instance.
number
High Capacity
The object identifier of the particular variable to be sampled. Only variables that resolve to an
Alarm Variable
ASN.1 primitive type of integer.
High Capacity
The interval in seconds over which the data is sampled and compared with the rising and
Alarm interval
falling thresholds. The range is 1to 2147483647.
High Capacity
The method of sampling the selected variable and calculating the value to be compared
Alarm Sample Type
against thresholds. Possible types are Absolute or Delta.
Rising-Threshold
High capacity alarm rising threshold absolute value high. The upper 32 bits of the absolute
High Value
value for threshold for the sampled statistics.
Rising-Threshold
High capacity alarm rising threshold absolute value low. The lower 32 bits of the absolute
Low Value
value for threshold for the sampled statistics.
Falling-Threshold
High capacity alarm falling threshold absolute value high. The upper 32 bits of the absolute
High Value
value for threshold for the sampled statistic.
Falling-Threshold
High capacity alarm falling threshold absolute value high. The upper 32 bits of the absolute
Low Value
value for threshold for the sampled statistic.
Rising/Falling/
High capacity alarm startup alarm that may be sent. Possible values are Rising Alarm, Falling
Rising-Falling
Alarm or both.
Owner String
High capacity alarm owner. The owner string associated with the entry.
no rmon hcalarm
This command deletes the rmon hcalarm entry.
Format
no rmon hcalarm <alarm number>
Mode
Global Config

rmon event

This command sets the rmon event entry in the RMON event mib group.
Format
rmon event <event number> [description|log|owner|trap]
Mode
Global Config