ProSafe XSM7224S Managed Stackable Switch CLI Manual, Software Version 9.0

show vlan port

This command displays VLAN port information.
Format
show vlan port {<unit/slot/port> | all}
Mode
• Privileged EXEC
• User EXEC
Term
Definition
Interface
Valid slot and port number separated by forward slashes. It is possible to set the
parameters for all ports by using the selectors on the top line.
Port VLAN ID
The VLAN ID that this port will assign to untagged frames or priority tagged frames
received on this port. The value must be for an existing VLAN. The factory default is 1.
Acceptable
The types of frames that may be received on this port. The options are 'VLAN only' and
Frame Types
'Admit All'. When set to 'VLAN only', untagged frames or priority tagged frames received
on this port are discarded. When set to 'Admit All', untagged frames or priority tagged
frames received on this port are accepted and assigned the value of the Port VLAN ID for
this port. With either option, VLAN tagged frames are forwarded in accordance to the
802.1Q VLAN specification.
Ingress
May be enabled or disabled. When enabled, the frame is discarded if this port is not a
Filtering
member of the VLAN with which this frame is associated. In a tagged frame, the VLAN is
identified by the VLAN ID in the tag. In an untagged frame, the VLAN is the Port VLAN ID
specified for the port that received this frame. When disabled, all frames are forwarded in
accordance with the 802.1Q VLAN bridge specification. The factory default is disabled.
GVRP
May be enabled or disabled.
Default Priority
The 802.1p priority assigned to tagged packets arriving on the port.

show vlan association subnet

This command displays the VLAN associated with a specific configured IP-Address and net mask.
If no IP address and net mask are specified, the VLAN associations of all the configured IP-
subnets are displayed.
Format
show vlan association subnet [<ipaddr> <netmask>]
Mode
Privileged EXEC