JunosE 11.2.x Command Reference Guide A to M
debounce-interval
Syntax
Release Information
Description
Options
Mode
476
debounce-interval seconds
no debounce-interval
Command introduced in JunosE Release 9.3.0.
Modifies the minimum time an Ethernet interface must maintain a given state—for
example, up or down—before the interface notifies the upper-layer protocols of the state
change. The no version restores the default value, 1 second.
NOTE: You can configure this command only if you have enabled the debounce timer
feature using the debounce command.
seconds—Interval for which an interface must maintain a given state before the interface
reports the state change to the upper-layer protocols. Number in the range 1–5 seconds;
default value is 1 second.
Interface Configuration