atm atm1483 auto-configure
Syntax
Release Information
Description
Options
Mode
150
atm atm1483 auto-configure upperInterfaceType
[ lockout-time { minValue maxValue | none } ]
no atm atm1483 auto-configure upperInterfaceType [ lockout-time ]
Command introduced before JunosE Release 7.1.0.
Specifies one or more types of dynamic upper interface encapsulations that are accepted
or detected by a dynamic ATM 1483 subinterface. Optionally, specifies the lockout time
range for the encapsulation type. You can issue this command repeatedly in Profile
Configuration mode to include autodetection of multiple upper interface encapsulation
types within the base profile for a dynamic ATM 1483 subinterface. The no version
terminates detection of the specified encapsulation type.
NOTE: Encapsulation type lockout is available for bridged Ethernet, IP, PPP, and PPPoE
encapsulation types.
upperInterfaceType—One of the following dynamic encapsulation types:
bridgedEthernet
ip
ppp
pppoe
minValue—Minimum lockout time in the range 1–86400 seconds (24 hours); default
value is 1 second
maxValue—Maximum lockout time in the range 1–86400 seconds (24 hours); default
value is 300 seconds (5 minutes)
none—Disables lockout for the specified dynamic encapsulation type
Profile Configuration