Drive-Cliq Component Parameter Index / Dq Para_Index; Drive-Cliq Component Read Parameter Value / Read Dq Value; Drive-Cliq Component Versions / Dq Comp Version; Firmware Update Automatic / Fw Update Auto - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p7822

DRIVE-CLiQ component parameter index / DQ para_index

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the parameter index to access a parameter of a DRIVE-CLiQ component.
Dependency:
Refer to: p7820, p7821, r7823
r7823

DRIVE-CLiQ component read parameter value / Read DQ value

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the parameter value read from the DRIVE-CLiQ component.
Dependency:
Refer to: p7820, p7821, p7822
r7825[0...6]

DRIVE-CLiQ component versions / DQ comp version

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the firmware and EEPROM versions of the DRIVE-CLiQ component selected using p7828[1].
Index:
[0] = Reference firmware version
[1] = Actual firmware version
[2] = EEPROM0 version
[3] = EEPROM1 version
[4] = EEPROM2 version
[5] = EEPROM3 version
[6] = EEPROM4 version
Dependency:
Refer to: p7828
Note:
Re index 0:
Firmware version on the memory card/device memory.
Re index 1:
Actual firmware version of the DRIVE-CLiQ component.
Re index 2 ... 6:
Actual EEPROM version of the DRIVE-CLiQ component.
p7826

Firmware update automatic / FW update auto

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the behavior for the automatic firmware update of the DRIVE-CLiQ components.
296
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents