Pn Subslot Controller Assignment / Pn Subslot Assign; Cbe2X Subslot Controller Assignment / Cbe2X Subslot; Cbe2X Ip Address Remote Controller 1 / Cbe2X Ip Rem Ctrl1 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
The combination of device ID (r8909) and DAP ID (r8959) uniquely identifies a PROFINET access point.
Note:
DAP ID: Device Access Point ID
DAP ID = 20007 hex: SINAMICS CBE20 V4.5
DAP ID = 20008 hex: SINAMICS CBE20 V4.6
DAP ID = 20009 hex: SINAMICS CBE20 V4.7
DAP ID = 20209 hex: SINAMICS CBE25 V4.7
r8960[0...2]

PN subslot controller assignment / PN subslot assign

All objects
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
0
Description:
Displays the controller assignment of a PROFINET subslot on the actual drive object.
Index:
[0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Note:
Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
r8970[0...2]

CBE2x subslot controller assignment / CBE2x subslot

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20),
0
DC_CTRL (PROFINET
CBE20), DC_CTRL_R
(PROFINET CBE20),
DC_CTRL_R_S
(PROFINET CBE20),
DC_CTRL_S
(PROFINET CBE20),
TM150 (PROFINET
CBE20), TM15DI_DO
(PROFINET CBE20),
TM31 (PROFINET
CBE20)
Description:
Displays the controller assignment of a PROFINET subslot on the actual drive object.
Index:
[0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Dependency:
Refer to: r8971, r8972
Note:
Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
r8971[0...3]

CBE2x IP Address Remote Controller 1 / CBE2x IP Rem Ctrl1

CU_DC (PROFINET
Can be changed: -
CBE20), CU_DC_R
Data type: Unsigned8
(PROFINET CBE20),
P-Group: -
CU_DC_R_S
Not for motor type: -
(PROFINET CBE20),
CU_DC_S
Min
(PROFINET CBE20)
0
Description:
Displays the IP address of the first PROFINET controller connected with the device via CBE20/CBE25.
348
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-