p51826[0...2]
Armature current converter firing pulse chopping times / Pulse chop t
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [µs]
Description:
Sets the times for firing pulse chopping on the armature current converter.
Index:
[0] = Length of first pulse
[1] = Length additional pulses
[2] = Break length
Note:
The parameter is only effective on the Control Module.
Block pulses are generated (i.e. firing pulses without pulse chopping) with the following setting:
- p51826[0] = 105 µs
- p51826[1] = 105 µs
- p51826[1] = 0 µs
p51829[0...2]

Heat sink temperature threshold / Htsk temp thresh

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [°C]
Description:
Sets the threshold for temperature monitoring on the Control Module.
Index:
[0] = Temperature sensor 1 / XT5 / A7109
[1] = Temperature sensor 2 / XT6 / A7109
[2] = Temperature sensor 3 / XT7 / A7116
Dependency:
Refer to: p51830
Refer to: F60067
Note:
The parameter is only effective on the Control Module.
p51830[0...2]

Heat sink temperature sensor type / Htsk temp type

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the sensor type for the temperature sensors on the Control Module.
Value:
0:
1:
2:
Index:
[0] = Temperature sensor 1 / XT5 / A7109
[1] = Temperature sensor 2 / XT6 / A7109
[2] = Temperature sensor 3 / XT7 / A7116
Dependency:
Refer to: p51829
Refer to: F60067
Note:
The NTC temperature sensor should be connected at module A7109 or A7116 at terminal XT5, XT6 or XT7.
The parameter is only effective on the Control Module.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
No temperature sensor present
NTC with 6.8 kOhm
NTC with 10 kOhm
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
105 [µs]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
200.0 [°C]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6860, 6965
Unit selection: -
Expert list: 1
Factory setting
[0] 50 [µs]
[1] 35 [µs]
[2] 70 [µs]
Access level: 2
Func. diagram: 8048
Unit selection: -
Expert list: 1
Factory setting
90.0 [°C]
Access level: 2
Func. diagram: 8048
Unit selection: -
Expert list: 1
Factory setting
0
553