Bi: Cud Analog Input 0 Inversion / Cud Ai 0 Inv; Cud Analog Input 0 Smoothing Time Constant / Cud Ai 0 T; Bi: Cud Analog Input 0 Signal Source For Enable; Cud Analog Input 0 Simulation Setpoint / Cud Ai 0 Sim Setp - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50704

BI: CUD analog input 0 inversion / CUD AI 0 inv

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for inverting the signal from analog input 0 (X177.25/26) on the CUD.
1 signal: Inversion
0 signal: No inversion
p50705

CUD analog input 0 smoothing time constant / CUD AI 0 T

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0 [ms]
Description:
Sets the time constant for smoothing the signal from analog input 0 (X177.25/26) on the CUD.
p50706
BI: CUD analog input 0 signal source for enable / CUD AI 0 ena sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for enabling analog input 0 (X177.25/26) on the CUD.
Note:
1 signal: Analog input enabled
0 signal: Analog input not enabled (r52011 = 0%)
p50707

CUD analog input 0 simulation setpoint / CUD AI 0 sim setp

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-130.0 [%]
Description:
Sets the setpoint for the simulation of analog input 0 (X177.25/26) on the CUD.
Dependency:
Refer to: p50709
Note:
Simulation is selected using p50709 = 1.
p50708
Activation of analog input synchronization / AI sync act
DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to activate/de-activate the synchronization of the analog inputs of two Control Unit DC MASTERs (CUDs).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
130.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 2075
Unit selection: -
Expert list: 1
Factory setting
0.0 [%]
Access level: 2
Func. diagram: 2083
Unit selection: -
Expert list: 1
Factory setting
0
501

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents