2 Parameters
2.2 List of parameters
Dependency:
Refer to: p51823, p51824
Danger:
The following applies for p51852 > 0:
Incorrect setting of parameter p51853 leads to damaging or destruction of the power unit!
Note:
The following applies for the DC converter:
p51852 = 0: p51853 is not active
p51852 > 0: p51853 is active
The following applies for the Control Module:
p51852 = 0: p51823 is active
p51852 > 0: p51853 is active, p51823 is not active
p51854

Armature voltage sensing configuration / Va_sens config

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the configuration for the armature voltage sensing.
Value = 0:
The device-internal armature voltage sensing is effective.
Value = 1:
An external armature voltage sensing is entered via analog input 2 (X177.29/30). The device-internal armature
voltage sensing is not effective.
Value = 2: both
Value:
0:
1:
2:
Dependency:
Refer to: p51823, p51824
Notice:
The following applies for p51854 = 0 --> 1 or 2:
The device must be restarted. Only then does the armature voltage sensing operate correctly via analog input 2.
Note:
AI: Analog Input
p51855
Armature voltage sensing analog input reference voltage / Va_sens AI V_ref
DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
10.000 [V]
Description:
Sets the armature voltage, which corresponds to a +10 V voltage at analog input 2 (X177.29/30).
Dependency:
Refer to: p51854
Note:
The parameter is only effective for p51854 = 1.
p51861[0...n]

Capacitance of the DC link capacitor / Capac_DClink

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.000 [µF]
Description:
Load connection: capacitance of the DC link capacitor
558
Va sensing internal
Va sensing via AI 2 (X177.29/30)
Va sensing internal & via AI 2 (X177.29/30)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2000.000 [V]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
10000000.000 [µF]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 6902
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6902
Unit selection: -
Expert list: 1
Factory setting
10.000 [V]
Access level: 3
Func. diagram: 6902
Unit selection: -
Expert list: 1
Factory setting
1000.000 [µF]