Co: Armature Firing Angle After Limiting / Fir Ang Aft Lim; Co: Armature Firing Angle Before Limiting / Fir Ang Bef Lim; Co: Cl-Loop Arm Curr Ctrl Prectr Value + Arm Curr Controller Output; Co: Armature Current Flow Duration / Arm I_Flow Dur - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Scaling:
0 % corresponds to 0 °C
100 % corresponds to 100 °C
Dependency:
The parameter is only valid for the following temperature sensors with a continuous characteristic:
- KTY84 (p50490 = 1)
- PT100 (p50490 = 6)
- NTC thermistor K227 (p50490 = 7)
- PT1000 (p50490 = 8)
Refer to: p50490
Note:
If p50490 = 0, 2 to 5, a value of 0 is displayed.
r52100

CO: Armature firing angle after limiting / Fir ang aft lim

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the armature firing angle after limiting by the auto-reversing stage.
r52101

CO: Armature firing angle before limiting / Fir ang bef lim

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the armature firing angle before limiting by the auto-reversing stage.
r52102
CO: Cl-loop arm curr ctrl prectr value + arm curr controller output / Ia ctr prec+outp
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the output to the armature gating module (pre-control value + armature current
controller output).
r52103

CO: Armature current flow duration / Arm I_flow dur

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the armature current flow duration/time ratio between 2 consecutive firing pulses.
566
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 6860
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6860, 6900
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 6855
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 6850
Unit selection: -
Expert list: 1
Factory setting
- [%]
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents