Bo: Power On Delay Signal / Power On T_Delay; Drive-Cliq Diagnostic Error Counter Connection / Dqdiag Err Counter; Drive-Cliq Diagnostic Configuration / Dq Diag Config - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r9935.0

BO: POWER ON delay signal / POWER ON t_delay

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Unsigned8
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Display and binector output for a delay after POWER ON.
After power-on, binector output r9935.0 is set with the start of the first sampling time and is again reset after approx.
100 ms.
Bit field:
Bit
00
r9936[0...199]

DRIVE-CLiQ diagnostic error counter connection / DQdiag err counter

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: Integer32
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the error counter for the individual DRIVE-CLiQ connections/cables.
r9936[0]: sum of the error counter for all connections
r9936[1]: not used
r9936[2]: error counter for the feeder cable to DRIVE-CLiQ components with component number 2
...
r9936[199]: error counter for the feeder cable to DRIVE-CLiQ components with component number 199
The feeder cable is the DRIVE-CLiQ cable that is connected to a component in the direction of the Control Unit.
Dependency:
Refer to: p9937, p9938
p9937

DRIVE-CLiQ diagnostic configuration / DQ diag config

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned16
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the configuration for the DRIVE-CLiQ diagnostics (error counter r9936).
Using this function, connections and cables of DRIVE-CLiQ connections can be checked for transfer errors. The error
counter is evaluated in the PHY blocks involved.
Bit field:
Bit
00
08
Dependency:
Refer to: r9936, p9938
Note:
Re bit 00:
To activate this function, p9938 must be set to 0 (inactive).
After changing the error counter (r9936), an appropriate alarm is output.
The alarm automatically disappears after 5 seconds.
Re bit 08:
With p9937.8 = 1, the error counters are reset (r9936[0...199]).
After the reset, p9937.8 is automatically set to 0.
366
Signal name
POWER ON delay signal
Signal name
Alarm for connection error
Reset error counter
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
No
No
SINAMICS DCM
FP
-
FP
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents