Motorized Potentiometer Activate Ramp-Function Generator; Ci: Motorized Potentiometer Signal Source For Automatic Setpoint; Motorized Potentiometer Ramp-Up Time / Motp T_R-Up; Motorized Potentiometer Ramp-Down Time / Motp T_R-Dn - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Value:
0:
1:
p50460[0...n]
Motorized potentiometer activate ramp-function generator / Mot pot act RFG
DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to activate/de-activate the ramp-function generator on the motorized potentiometer.
Value:
0:
1:
p50461[0...n]
CI: Motorized potentiometer signal source for automatic setpoint / MotP aut s sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the ramp-function generator's setpoint in automatic mode on the motorized potentiometer.
p50462[0...n]

Motorized potentiometer ramp-up time / MotP t_r-up

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.01 [s]
Description:
Sets the ramp-up time on the motorized potentiometer.
p50463[0...n]

Motorized potentiometer ramp-down time / MotP t_r-dn

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.01 [s]
Description:
Sets the ramp-down time on the motorized potentiometer.
p50464[0...n]
Motorized potentiometer time difference for dy/dt / MotP t_dif dy/dt
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.01 [s]
Description:
Sets the time difference for the ramp-function generator dy/dt on the motorized potentiometer.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
1 level
0/1 edge
RFG de-activated in automatic mode
RFG activated in automatic and manual modes
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
300.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
300.00 [s]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
300.00 [s]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
461

Hide quick links:

Advertisement

Table of Contents
loading