r53200.0...1

CO/BO: Motorized potentiometer state / MotP state

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the state on the motorized potentiometer.
Bit field:
Bit
00
01
r53210.0...5

CO/BO: Sequence control output signals / Seq_ctrl outp_sig

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and BICO output for the sequence control output signals.
Bit field:
Bit
00
01
02
03
04
05
r53220.0...5

CO/BO: Fuses at X23B state / Fuses X23B

DC_CTRL
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output/binector output for the state of the fuses at X23B.
The fuses are monitored via connection A7109:X23B or A7112:X23B.
Bit field:
Bit
00
01
02
03
04
05
Dependency:
Refer to: p51831
Refer to: F60204
Note:
The fuses are only set to "OK" in operating state o7.0. The fuses are set to "ruptured" in all other operating states.
The parameter is only relevant for the Control Module.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
Output is zero (y = 0)
Ramp-up/ramp-down complete (y = x)
Signal name
Close brake
Close brake inverted
Switch on auxiliaries
Switch on auxiliaries inverted
Automatic restart active
Automatic restart active inverted
Signal name
Fuse XS1
Fuse XS2
Fuse XS3
Fuse XS4
Fuse XS5
Fuse XS6
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Okay
Okay
Okay
Okay
Okay
Okay
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 2
Func. diagram: 2585, 2651,
2750
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
Access level: 2
Func. diagram: 6957
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Ruptured
Ruptured
Ruptured
Ruptured
Ruptured
Ruptured
FP
-
-
FP
2585,
2750
2750
2651
2651
2651,
2750
2651,
2750
FP
-
-
-
-
-
-
641