p50124[0...n]

Field current for motor flux 20 % / I_field flux 20%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 20 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50123 and less than p50125 can be set.
p50125[0...n]

Field current for motor flux 25 % / I_field flux 25%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 25 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50124 and less than p50126 can be set.
p50126[0...n]

Field current for motor flux 30 % / I_field flux 30%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 30 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50125 and less than p50127 can be set.
p50127[0...n]

Field current for motor flux 35 % / I_field flux 35%

DC_CTRL
Can be changed: T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.0 [%]
Description:
Setting of the field current for a motor flux of 35 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50126 and less than p50128 can be set.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
100.0 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
14.7 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
18.4 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
22.0 [%]
Access level: 3
Func. diagram: 6900, 6910
Unit selection: -
Expert list: 1
Factory setting
25.7 [%]
405