Bi: Signal Source For Master Switch Setpoint Step S4 /; Master Switch Setpoint Step S1 Value / Set Step S1 Value; Master Switch Setpoint Step S2 Value / Set Step S2 Value; Master Switch Setpoint Step S3 Value / Set Step S3 Value - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p51664
BI: Signal source for master switch setpoint step S4 / Set step S4 sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for changing over to setpoint step S4 on the 4-step master switch.
p51665

Master switch setpoint step S1 value / Set step S1 value

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the setpoint for setpoint step S1 on the 4-step master switch.
p51666

Master switch setpoint step S2 value / Set step S2 value

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the setpoint for setpoint step S2 on the 4-step master switch.
p51667

Master switch setpoint step S3 value / Set step S3 value

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the setpoint for setpoint step S3 on the 4-step master switch.
p51668
Master switch setpoint step S4 value / Set step S4 value
DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [%]
Description:
Sets the setpoint for setpoint step S4 on the 4-step master switch.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
110.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
110.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
110.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
110.00 [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3105
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3105
Unit selection: -
Expert list: 1
Factory setting
10.00 [%]
Access level: 2
Func. diagram: 3105
Unit selection: -
Expert list: 1
Factory setting
25.00 [%]
Access level: 2
Func. diagram: 3105
Unit selection: -
Expert list: 1
Factory setting
40.00 [%]
Access level: 2
Func. diagram: 3105
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]