r0035

CO: Motor temperature / Mot temp

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
- [°C]
Description:
Display and connector output for the actual temperature in the motor.
Note:
For r0035 not equal to -200.0 °C, the following applies:
- this temperature display is valid.
- a KTY sensor is connected.
For r0035 equal to -200.0 °C, the following applies:
- this temperature display is not valid (temperature sensor error).
- A PTC sensor or bimetallic NC contact is connected.
p0045

Display values smoothing time constant / Disp_val T_smooth

DC_CTRL,
Can be changed: U, T
DC_CTRL_R,
Data type: FloatingPoint32
DC_CTRL_R_S,
P-Group: -
DC_CTRL_S
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the smoothing time constant for the following display values:
r0063[1], r0068[1], r0080[1], r0082[1]
r0046.0...31

CO/BO: Missing enable sig / Missing enable sig

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Displays, signals
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Display and BICO output for missing enable signals that are preventing the closed-loop drive control from being
commissioned.
Bit field:
Bit
00
01
02
03
10
11
12
16
17
18
19
26
28
30
31
Dependency:
Refer to: r0002
Note:
The value r0046 = 0 indicates that all enable signals are present.
Bit 00 = 1 (enable signal missing), if:
- the signal source in p0840 is a 0 signal.
- there is a "switching on inhibited".
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
OFF1 enable missing
OFF2 enable missing
OFF3 enable missing
Operation enable missing
Ramp-function generator enable missing
Ramp-function generator start missing
Setpoint enable missing
OFF1 enable internal missing
OFF2 enable internal missing
OFF3 enable internal missing
Pulse enable internal missing
Drive inactive or not operational
Brake open missing
Speed controller inhibited
Jog setpoint active
Calculated: -
Dyn. index: -
Unit group: 21_1
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7008, 8017
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 2
Func. diagram: 6810, 6850
Unit selection: -
Expert list: 1
Factory setting
1.00 [ms]
Access level: 1
Func. diagram: 2655
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-