p2127[0...19]

Change acknowledge mode mode / Chng ackn mode

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S, DC_CTRL,
P-Group: Messages
DC_CTRL_R,
Not for motor type: -
DC_CTRL_R_S,
DC_CTRL_S
Min
1
Description:
Sets the acknowledge mode for selected fault.
Value:
1:
2:
3:
Dependency:
Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2126
Notice:
It is not possible to re-parameterize the acknowledge mode for a fault in the following cases:
- Fault number does not exist (exception value = 0).
- Message type is not "fault" (F).
- Acknowledge mode is not permissible for the set fault number.
Note:
Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has been
resolved.
The acknowledge mode can only be changed for faults with the appropriate identification.
Example:
F12345 and acknowledge mode = IMMEDIATELY (POWER ON)
--> The acknowledge mode can be changed from IMMEDIATELY to POWER ON.
p2127[0...19]
Change acknowledge mode mode / Chng ackn mode
TM150, TM15DI_DO,
Can be changed: U, T
TM31
Data type: Integer16
P-Group: Messages
Not for motor type: -
Min
1
Description:
Sets the acknowledge mode for selected fault.
Value:
1:
2:
3:
Dependency:
Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2126
Notice:
It is not possible to re-parameterize the acknowledge mode for a fault in the following cases:
- Fault number does not exist (exception value = 0).
- Message type is not "fault" (F).
- Acknowledge mode is not permissible for the set fault number.
Note:
Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has been
resolved.
The acknowledge mode can only be changed for faults with the appropriate identification.
Example:
F12345 and acknowledge mode = IMMEDIATELY (POWER ON)
--> The acknowledge mode can be changed from IMMEDIATELY to POWER ON.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Acknowledgment only using POWER ON
Ack IMMEDIATELY after the fault cause has been removed
Acknowledgement only for PULSE INHIBIT
Acknowledgment only using POWER ON
Ack IMMEDIATELY after the fault cause has been removed
Acknowledgement only for PULSE INHIBIT
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 8075
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 8050, 8075
Unit selection: -
Expert list: 1
Factory setting
1
175

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents