Co: Rfg Speed Setpoint Output / Rfg N_Set Outp; Co: Rfg Dy/Dt Rise In Relation To P50542 / Rfg Dy/Dt P50542; Co: Rfg Setpoint Before Ramp-Function Generator; Co: Setpoint Processing Output To Ramp-Function Generator - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r52190

CO: RFG speed setpoint output / RFG n_set outp

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the speed setpoint calculated by the ramp-function generator.
r52191

CO: RFG dy/dt rise in relation to p50542 / RFG dy/dt p50542

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the rise of the ramp-function generator output in relation to the time set in p50542.
Dependency:
Refer to: p50542
r52192
CO: RFG setpoint before ramp-function generator / RFG set bef RFG
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the setpoint before the ramp-function generator.
r52193
CO: Setpoint processing output to ramp-function generator / Outp to RFG
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the setpoint to the ramp-function generator.
Dependency:
Refer to: p50648
r52194
CO: Setpoint processing setpoint after reduction / Set after reduc
DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Display and connector output for the sum "main setpoint (limited) + additional setpoint" after setpoint reduction.
Dependency:
Refer to: p51607, p51608, r52195
Note:
Setpoint reduction is set via p51608 and activated/de-activated via binector input p51607.
582
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 3150, 3151,
3152, 3155
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 3152
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 3151, 3152
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 1
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
- [%]
SINAMICS DCM