Encoder Configuration Supported / Enc_Config Supp; Sensor Module Properties / Sm Properties - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
17
20
21
22
23
Dependency:
Refer to: p0404
Note:
ZM: Zero mark
This parameter is only used for diagnostics.
A value of zero is displayed if an encoder is not present.
Re bit 20, 21 (voltage level 5 V, voltage level 24 V):
The voltage level cannot be detected. Therefore, these bits are always set to 0.
r0456[0...2]

Encoder configuration supported / Enc_config supp

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the encoder configuration supported by the Sensor Module.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Bit field:
Bit
00
01
02
03
04
05
06
08
09
10
11
12
13
14
15
16
17
20
21
22
23
Dependency:
Refer to: p0404
Note:
ZM: Zero mark
This parameter is only used for diagnostics.
A value of zero is displayed if an encoder is not present.
r0458[0...2]

Sensor Module properties / SM properties

DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: Encoder
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Sets the Sensor Module configuration.
80
Track A/B analog
Voltage level 5 V
Voltage level 24 V
Remote sense (only SMC30)
Resolver excit
Signal name
Linear encoder
Absolute encoder
Multiturn encoder
Track A/B sq-wave
Track A/B sine
Track C/D
Hall sensor
EnDat encoder
SSI encoder
DRIVE-CLiQ encoder
Digital encoder
Equidistant zero mark
Irregular zero mark
Distance-coded zero mark
Commutation with zero mark (not ASM)
Acceleration
Track A/B analog
Voltage level 5 V
Voltage level 24 V
Remote sense (only SMC30)
Resolver excit
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 3
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links: