Terminal Module Firmware Version / Tm Fw Version; Number Of Command Data Sets (Cds) / Cds Count; Number Of Drive Data Sets (Dds) / Dds Count; Encoder 1 Encoder Data Set Number / Enc 1 Eds Number - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r0158

Terminal Module firmware version / TM FW version

TM150, TM15DI_DO,
Can be changed: -
TM31
Data type: Unsigned32
P-Group: Terminals
Not for motor type: -
Min
-
Description:
Displays the firmware version of the Terminal Module.
Dependency:
Refer to: r0018, r0148, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
p0170

Number of Command Data Sets (CDS) / CDS count

DC_CTRL,
Can be changed: C1(3)
DC_CTRL_R,
Data type: Unsigned8
DC_CTRL_R_S,
P-Group: Commands
DC_CTRL_S
Not for motor type: -
Min
2
Description:
Sets the number of Command Data Sets (CDS).
Note:
It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
p0180

Number of Drive Data Sets (DDS) / DDS count

DC_CTRL,
Can be changed: C1(3)
DC_CTRL_R,
Data type: Unsigned8
DC_CTRL_R_S,
P-Group: Data sets
DC_CTRL_S
Not for motor type: -
Min
4
Description:
Sets the number of Drive Data Sets (DDS).
p0187[0...n]

Encoder 1 encoder data set number / Enc 1 EDS number

DC_CTRL,
Can be changed: C1(4)
DC_CTRL_R,
Data type: Unsigned8
DC_CTRL_R_S,
P-Group: Data sets
DC_CTRL_S
Not for motor type: -
Min
0
Description:
Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 1.
The value corresponds to the number of the assigned encoder data set.
Example:
Encoder data set 0 should be assigned to encoder 1 in drive data set 2.
--> p0187[2] = 0
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
99
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 2
Func. diagram: 8565
Unit selection: -
Expert list: 1
Factory setting
4
Access level: 3
Func. diagram: 8570
Unit selection: -
Expert list: 1
Factory setting
99
59