Bi: Tm15Di/Do Signal Source For Terminal Di/Do 5 / Tm15D S_Src Di/Do5; Bi: Tm15Di/Do Signal Source For Terminal Di/Do 6 / Tm15D S_Src Di/Do6; Bi: Tm15Di/Do Signal Source For Terminal Di/Do 8 / Tm15D S_Src Di/Do8 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p4035

BI: TM15DI/DO signal source for terminal DI/DO 5 / TM15D s_src DI/DO5

TM15DI_DO
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 5 (X520.7) of Terminal Module 15 (TM15).
Note:
Prerequisite: The DI/DO must be set as an output (p4028.5 = 1).
DI/DO: Bidirectional Digital Input/Output
p4036

BI: TM15DI/DO signal source for terminal DI/DO 6 / TM15D s_src DI/DO6

TM15DI_DO
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 6 (X520.8) of Terminal Module 15 (TM15).
Note:
Prerequisite: The DI/DO must be set as an output (p4028.6 = 1).
DI/DO: Bidirectional Digital Input/Output
p4037
BI: TM15DI/DO signal source for terminal DI/DO 7 / TM15D s_src DI/DO7
TM15DI_DO
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 7 (X520.9) of Terminal Module 15 (TM15).
Note:
Prerequisite: The DI/DO must be set as an output (p4028.7 = 1).
DI/DO: Bidirectional Digital Input/Output
p4038

BI: TM15DI/DO signal source for terminal DI/DO 8 / TM15D s_src DI/DO8

TM15DI_DO
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 8 (X521.2) of terminal module 15 (TM15).
Note:
Prerequisite: The DI/DO must be set as an output (p4028.8 = 1).
DI/DO: Bidirectional Digital Input/Output
218
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 9400
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 9400
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 9400
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 9401
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading