Electronic Power Supply Voltage Display / Electr Supp V Disp; Electronic Power Supply Failure Duration / Electr Supp T_Fail; Armature Power Unit Compensation Values / Pu Arm Comp Val; Field Power Unit Compensation Values / Pu Field Comp Val - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r50823[0...1]

Electronic power supply voltage display / Electr supp V disp

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [V]
Description:
Displays the voltages for the electronic power supply.
Index:
[0] = P10 (+10 V)
[1] = N10 (-10 V)
Dependency:
Refer to: r50824
Refer to: F60091, F60092
Note:
For r50823[0]:
A voltage value outside the permissible limits will trigger fault F60091.
For r50823[1]:
A voltage value outside the permissible limits will trigger fault F60092.
r50824

Electronic power supply failure duration / Electr supp t_fail

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
- [ms]
Description:
Displays the failure duration for the electronic power supply.
Dependency:
Refer to: r50823
r50825[0...29]

Armature power unit compensation values / PU arm comp val

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the compensation values for the armature power unit.
r50826[0...15]

Field power unit compensation values / PU field comp val

DC_CTRL
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the compensation values for the field power unit.
522
Calculated: -
Dyn. index: -
Unit group: -
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 1
Func. diagram: 8048
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 1
Func. diagram: 8048
Unit selection: -
Expert list: 1
Factory setting
- [ms]
Access level: 4
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-