Voltage Sensing Communication Error Counter / V_Sens Comm_Err; Reset Thyristor Load Data / Thyr_Load Reset; Diagnostics Memory Message Number / Diag_Mem Msg_No; Gating Module Serial Number / Gate_Mod Ser_No. - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r50836[0...3]

Voltage sensing communication error counter / V_sens comm_err

DC_CTRL
Can be changed: -
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the communication error for armature and field voltage sensing.
Index:
[0] = Number of CRC errors armature
[1] = Number of communication errors armature
[2] = Number of CRC errors field
[3] = Number of communication errors field
p50837[0...11]

Reset thyristor load data / Thyr_load reset

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to reset the thyristor load data for a thyristor.
Value:
0:
1:
Index:
[0] = Thyristor X11
[1] = Thyristor X12
[2] = Thyristor X13
[3] = Thyristor X14
[4] = Thyristor X15
[5] = Thyristor X16
[6] = Thyristor X21
[7] = Thyristor X22
[8] = Thyristor X23
[9] = Thyristor X24
[10] = Thyristor X25
[11] = Thyristor X26
Note:
It is only permissible to reset the thyristor load data after a thyristor has been replaced.
p50838[0...2]

Diagnostics memory message number / Diag_mem msg_no

DC_CTRL
Can be changed: U, T
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
60000
Description:
Sets message numbers for the diagnostics memory.
A trace is saved in the diagnostics file if one of these messages occurs.
r50840[0...31]

Gating module serial number / Gate_mod ser_no.

DC_CTRL
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the serial number of the gating module.
526
Do not reset data
Reset data
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
60999
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 8054
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 8052
Unit selection: -
Expert list: 1
Factory setting
60000
Access level: 1
Func. diagram: 6960
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents