Bi: Setpoint Processing Sig Source To Enable Neg Dir Of Rotation; Bi: Setpoint Processing Signal Source To Enable Pos Dir Of Rotation; Bi: Motorized Potentiometer Signal Source To Increase Setpoint; Bi: Motorized Potentiometer Signal Source To Lower Setpoint - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
[5] = Effective negative current limit
[6] = Effective speed controller proportional gain
p50671[0...n]
BI: Setpoint processing sig source to enable neg dir of rotation / Ena n dir r sig s
DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source to enable the negative direction of rotation.
Dependency:
Refer to: p50672
Note:
1 signal: Negative direction of rotation enabled
0 signal: Negative direction of rotation disabled
p50672[0...n]
BI: Setpoint processing signal source to enable pos dir of rotation / Ena p dir r sig s
DC_CTRL
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source to enable the positive direction of rotation.
Dependency:
Refer to: p50671
Note:
1 signal: Positive direction of rotation enabled
0 signal: Positive direction of rotation disabled
p50673[0...n]
BI: Motorized potentiometer signal source to increase setpoint / MotP incr sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source to increase the setpoint for the motorized potentiometer.
Dependency:
Refer to: p50471
Note:
This parameter is only effective in manual mode (p50471 = 0).
p50674[0...n]
BI: Motorized potentiometer signal source to lower setpoint / MotP lower sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source to lower the setpoint for the motorized potentiometer.
Dependency:
Refer to: p50471
Note:
This parameter is only effective in manual mode (p50471 = 0).
496
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 3135
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3110
Unit selection: -
Expert list: 1
Factory setting
0