Speed Controller Reference Model Damping / N_Ctrl Ref_M D; Speed Controller Reference Model Dead Time / N_Ctr Ref_M T_Dead; Speed Controller Reference Model Activation / N_Ctrl Ref_M Act; Ci: Speed Controller Reference Model Signal Source - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50238[0...n]

Speed controller reference model damping / n_ctrl ref_m d

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.000
Description:
Sets the damping of a PT2 element for the reference model of the speed controller.
Recommendation:
The reference model is correctly set when the characteristics of r52154 (reference model output) and r52167 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency:
In conjunction with p50237 and p50239, the characteristics (in time) of the P-controlled speed control loop can be
emulated.
Refer to: p50237, p50239
p50239[0...n]

Speed controller reference model dead time / n_ctr ref_m t_dead

DC_CTRL
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00
Description:
Sets the "fractional" dead time for the reference model of the speed controller.
This parameter emulates the computing dead time of the proportionally controlled speed control loop.
The multiplier set refers to the speed controller clock cycle.
Recommendation:
The reference model is correctly set when the characteristics of r52154 (reference model output) and r52167 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency:
In conjunction with p50237 and p50238, the characteristics (in time) of the P-controlled speed control loop can be
emulated.
Refer to: p50237, p50238
p50240[0...n]

Speed controller reference model activation / n_ctrl ref_m act

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to activate the influence of the reference model for the speed controller.
Value:
0:
1:
Dependency:
Refer to: p50241
p50241
CI: Speed controller reference model signal source / n_ctrl ref_m sig s
DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the input signal of the reference model for the speed controller.
Dependency:
Refer to: p50240
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Reference model not effective
Reference model effective
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
5.000
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
2.00
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6812
Unit selection: -
Expert list: 1
Factory setting
1.000
Access level: 2
Func. diagram: 6812
Unit selection: -
Expert list: 1
Factory setting
0.00
Access level: 2
Func. diagram: 6815
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 6815
Unit selection: -
Expert list: 1
Factory setting
52155[0]
427

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents