r3996[0...1]

Parameter write inhibit status / Par_write inhib st

All objects
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays whether writing to parameters is inhibited.
r3996[0] = 0:
Parameter write not inhibited.
0 < r3996[0] < 100:
Parameter write inhibited. The value shows how the calculations are progressing.
Index:
[0] = Progress calculations
[1] = Cause
Note:
Re index 1:
Only for internal Siemens troubleshooting.
r4021

TM15DI/DO digital inputs terminal actual value / TM15D DI act val

TM15DI_DO
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the
simulation mode (p4095.x = 1) to terminal mode (p4095.x = 0).
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Note:
If a DI/DO is parameterized as output (p4028.x = 1), then r4021.x = 0 is displayed.
DI/DO: Bidirectional Digital Input/Output
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Signal name
DI/DO 0 (X520.2)
DI/DO 1 (X520.3)
DI/DO 2 (X520.4)
DI/DO 3 (X520.5)
DI/DO 4 (X520.6)
DI/DO 5 (X520.7)
DI/DO 6 (X520.8)
DI/DO 7 (X520.9)
DI/DO 8 (X521.2)
DI/DO 9 (X521.3)
DI/DO 10 (X521.4)
DI/DO 11 (X521.5)
DI/DO 12 (X521.6)
DI/DO 13 (X521.7)
DI/DO 14 (X521.8)
DI/DO 15 (X521.9)
DI/DO 16 (X522.2)
DI/DO 17 (X522.3)
DI/DO 18 (X522.4)
DI/DO 19 (X522.5)
DI/DO 20 (X522.6)
DI/DO 21 (X522.7)
DI/DO 22 (X522.8)
DI/DO 23 (X522.9)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 9400, 9401,
9402
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
211

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents