2.2 List of parameters
p4781[0...1]

Trace physical address signal 1 / Trace PhyAddr Sig1

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the second signal to be traced.
The data type is defined using p4731.
Index:
[0] = Trace 0
[1] = Trace 1
p4782[0...1]

Trace physical address signal 2 / Trace PhyAddr Sig2

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the third signal to be traced.
The data type is defined using p4732.
Index:
[0] = Trace 0
[1] = Trace 1
p4783[0...1]

Trace physical address signal 3 / Trace PhyAddr Sig3

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the fourth signal to be traced.
The data type is defined using p4733.
Index:
[0] = Trace 0
[1] = Trace 1
p4784[0...1]

Trace physical address signal 4 / Trace PhyAddr Sig4

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the fifth signal to be traced.
The data type is defined using p4734.
Index:
[0] = Trace 0
[1] = Trace 1
272
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
SINAMICS DCM