2 Parameters
2.2 List of parameters
Note:
The valuation factors affect the set values of the following parameters:
- p50303: Ramp-up time 1
- p50304: Ramp-down time 1
- p50305: Initial rounding 1
- p50306: Final rounding 1
p50637[0...n]

BI: RFG parameter set 2 selection signal source / RFG par s 2 sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the selection of "ramp-function generator parameter set 2".
1 signal:
RFG parameter set 2 is effective (p50307, p50308, p50309, p50310).
Dependency:
Refer to: p50307, p50308, p50309, p50310, p50638
Refer to: F60041
Note:
The following applies as regards selection of ramp-function generator parameter set 2:
- This selection has a higher priority than selection by means of the ramp-up integrator.
- This selection has a lower priority than quick stop (OFF3); in other words, in the event of a quick stop (OFF3) the
values set in p50296, p50297, and p50298 become effective.
- A corresponding message is output if ramp-function generator parameter sets 2 and 3 are selected at the same
time.
p50638[0...n]

BI: RFG parameter set 3 selection signal source / RFG par s 3 sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the selection of "ramp-function generator parameter set 3".
1 signal:
RFG parameter set 3 is effective (p50311, p50312, p50313, p50314).
Dependency:
Refer to: p50311, p50312, p50313, p50314, p50637
Refer to: F60041
Note:
The following applies as regards selection of ramp-function generator parameter set 3:
- This selection has a higher priority than selection by means of the ramp-up integrator.
- This selection has a lower priority than quick stop (OFF3); in other words, in the event of a quick stop (OFF3) the
values set in p50296, p50297, and p50298 become effective.
- A corresponding message is output if ramp-function generator parameter sets 2 and 3 are selected at the same
time.
p50639[0...1]

CI: RFG signal source for setting value / RFG set val sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the ramp-function generator's setting values.
Index:
[0] = Setting value
[1] = Setting value if machine is not running
492
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3150
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3152
Unit selection: -
Expert list: 1
Factory setting
52167[0]