Macro Execution Actual / Macro Executed; Identification And Maintenance 4 Configuration / I&M 4 Config; Identification And Maintenance 1 / I&M 1 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

r8573[0...39]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
DC_CTRL,
Can be changed: -
DC_CTRL_R,
Data type: Unsigned32
DC_CTRL_R_S,
P-Group: -
DC_CTRL_S
Not for motor type: -
Min
-
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p1500
Note:
For a value = 9999999, the following applies: The read operation is still running.
r8585

Macro execution actual / Macro executed

All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the macro currently being executed on the drive object.
Dependency:
Refer to: p0015, p0700, p1000, p1500, r8570, r8571, r8572, r8573
p8805
Identification and maintenance 4 configuration / I&M 4 config
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the configuration for the content of identification and maintenance 4 (I&M 4, p8809).
Value:
0:
1:
Dependency:
For p8805 = 0, if the user writes at least one value in p8809[0...53], then p8805 is automatically set to = 1.
When p8805 is reset = 0, then the content of the factory setting is set in p8809.
Note:
Re p8805 = 0:
PROFINET I&M 4 (p8809) contains the information for the SI change tracking.
Re p8805 = 1:
PROFINET I&M 4 (p8809) contains the values written by the user.
p8806[0...53]
Identification and Maintenance 1 / I&M 1
CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned8
CU_DC_S
P-Group: -
Not for motor type: -
Min
-
Description:
Parameters for the PROFINET data set "Identification and Maintenance 1" (I&M 1).
This information is known as "System identifier" and "Location identifier".
Dependency:
Refer to: p8807, p8808
Notice:
Only characters belonging to the standard ASCII character set may be used (32 dec to 126 dec).
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Standard value for I&M 4 (p8809)
User value for I&M 4 (p8809)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting