Co: Function Generator Output Signal / Fg Outp_Sig; Bi: Function Generator Control / Fg Control; Function Generator Signal Shape / Fg Signal Shape; Function Generator Period / Fg Period Duration - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r4818

CO: Function generator output signal / FG outp_sig

CU_DC, CU_DC_R,
Can be changed: -
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
- [%]
Description:
Displays the output signal for the function generator.
Dependency:
Refer to: p4810
Note:
The value is displayed independently of the function generator mode.
p4819

BI: Function generator control / FG control

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Unsigned32 / Binary
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Sets the signal source to control the function generator.
When the function generator is running, signal generation is stopped with a 0 signal from BI: p4819 and p4800 is set
to 0.
Dependency:
Refer to: p4800
p4820

Function generator signal shape / FG signal shape

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: Integer16
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
1
Description:
Sets the signal to be generated for the function generator.
Value:
1:
2:
3:
4:
5:
p4821

Function generator period / FG period duration

CU_DC, CU_DC_R,
Can be changed: U, T
CU_DC_R_S,
Data type: FloatingPoint32
CU_DC_S
P-Group: Trace and function generator
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the period of the signal to be generated for the function generator.
Dependency:
Ineffective when p4820 = 4 (PRBS).
278
Square-wave
Staircase
Delta
Binary noise - PRBS (Pseudo Random Binary Signal)
Sine-wave
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
5
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
60000.00 [ms]
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
1000.00 [ms]