Ci: Signal Source For Creep Setpoint / Cr Set Sig S; Creep Setpoint Bypass Ramp-Function Generator / Cr Set Bypass Rfg; Ci: Creep Signal Source For Default Setpoint / Cr Def Set Sig S; Bi: Creep Signal Source For Shutdown / Cr Shutdn Sig S - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p50441[0...7]

CI: Signal source for creep setpoint / Cr set sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal sources for generating the creep setpoint (CO: r52201).
Dependency:
Refer to: r52201
p50442[0...7]

Creep setpoint bypass ramp-function generator / Cr set bypass RFG

DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to enable/disable the impact of the individual creep setpoints when generating signal r53170.12, "Bypass
ramp-function generator".
Value:
0:
1:
Note:
[0]: Enable bypassing of ramp-function generator at creep setpoint 0
...
[7]: Enable bypassing of ramp-function generator at creep setpoint 7
p50443[0...n]

CI: Creep signal source for default setpoint / Cr def set sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the default setpoint when creep is not selected.
p50444[0...n]

BI: Creep signal source for shutdown / Cr shutdn sig s

DC_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for shutting down/resetting the injection of the creep setpoint.
p50445
Creep setpoint level/edge / Cr set lev/ed
DC_CTRL
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets whether the ON command is triggered by a logic 1 level or a 0/1 edge.
460
Do not bypass
Bypass
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH8), 02/2015, 6RX1800-0ED76
Access level: 2
Func. diagram: 3130
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3130
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3130
Unit selection: -
Expert list: 1
Factory setting
52207[0]
Access level: 2
Func. diagram: 3130
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3130
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS DCM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents