Fixed Bit 4 / Fixed Bit 4; Fixed Bit 5 / Fixed Bit 5; Fixed Bit 6 / Fixed Bit 6; Fixed Bit 7 / Fixed Bit 7 - Siemens SINAMICS DCM List Manual

Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

p50425[0...n]

Fixed bit 4 / Fixed bit 4

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal level for fixed bit 4.
Value:
0:
1:
Dependency:
Refer to: r53230
Note:
This signal can be interconnected via binector output r53230.4.
p50426[0...n]

Fixed bit 5 / Fixed bit 5

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal level for fixed bit 5.
Value:
0:
1:
Dependency:
Refer to: r53230
Note:
This signal can be interconnected via binector output r53230.5.
p50427[0...n]

Fixed bit 6 / Fixed bit 6

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal level for fixed bit 6.
Value:
0:
1:
Dependency:
Refer to: r53230
Note:
This signal can be interconnected via binector output r53230.6.
p50428[0...n]

Fixed bit 7 / Fixed bit 7

DC_CTRL
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal level for fixed bit 7.
Value:
0:
1:
Dependency:
Refer to: r53230
Note:
This signal can be interconnected via binector output r53230.7.
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
Low
High
Low
High
Low
High
Low
High
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3100
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3100
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3100
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3100
Unit selection: -
Expert list: 1
Factory setting
0
457

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents